Showing results: 151 - 165 of 403 items found.
-
Vanguard Instruments Company, Inc.
The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers. The PCI-600 is versatile and can also be used in many other applications that require a high-current source.
-
Macintyre Electronic Design Associa
he MEDA turnkey closed loop magnetic field sources cancel the local ambient field as well as generate accurate and uniform magnetic fields in a control volume. The sources use Helmholtz coils driven by control currents to produce stable magnetic fields from 1 nT to 100,000 nT. The accuracy of the field in the control volume is better than 0.05% of the setting.
-
ElectroSensor™ -
Sonic Technology Inc.
This EMF detector is an unparalleled value that offers fast, reliable, and user-friendly measurements of electromagnetic pollution. Since man-made alternating current (AC) is different from naturally occurring EMF, some sources say that even extended exposure of as low as 2 milliGauss may be harmful. Fortunately, once EMF sources are identified with your ElectroSensor you can moderate your distance and exposure.
-
SCR ELEKTRONIKS
This equipment comprises of high current source for testing of circuit breakers with additional facility for temperature rise testing (thus incorporating testing for moulded case, vacuum & air circuit breakers as per IEC 60947-2). The system integrates a servo controlled source with closed loop current feedback to maintain the current constant. It has the necessary instrumentation for maintaining current at full load & other conditions arising in testing at high current. The bench has a PC based control system with temperature data logger (24 channel with ch-ch isolation amplifiers). The data logger displays as well as stores a set of temperature values with time.
-
MeasureReady™ 155 -
Lake Shore Cryotronics, Inc.
The MeasureReady™ 155 Precision I/V source combines premium performance with unprecedented simplicity for materials scientists and engineers requiring a precise source of current and voltage. Low RMS noise: from 200 nV (10 mV)/7 pA (1 µA). Bipolar, 4-quadrant power source. DC and AC modes supported up to 100 kHz*. Full scale ranges from 10 mV to 100 V (1 μA to 100 mA). 0.001% programming resolution (from 100 nV/10 pA.
-
Series 100 -
Pickering Electronics
The Pickering Series 100 is a complete range of Single-in- Line (SIL) reed relays primarily intended for direct drive from 4000B CMOS or similar low current sources. They feature a very low level of thermal EMF.
-
Megaron Ltd.
LLC "Megaron" develops and manufactures instruments for measuring parameters of various chemical current sources, devices for testing batteries. This equipment of varying complexity, from simple, designed for a specific battery, with the possibility to universal computer monitoring processes.
-
Digatron Power Electronics
The PowerNet Tester (BNT) is designed to test batteries, ultracaps and all other types of electrochemical power sources for 14 V and 42 V power net systems. Designed to test vehicle system batteries for 14V and 42V power net systems. But they may also be used for testing all other types of electrochemical power sources just by setting the required current and voltage values.
-
68DT1 -
North Atlantic Industries
The 68DT1 is a 3U OpenVPX™ board featuring up to 96-Channels of Standard Functionality (SF) DT1 module-type or Enhanced Functionality (EF) DT4 module-type Discrete I/O functions [foptioned, factory configurable].48-Channels are dedicated as input (voltage or contact sensing with programmable, pull-up/pull-down current sources). An additional 24 or 48-Channels are programmable for either input or output (current source, sink, or push-pull) switching up to 500 mA per channel from an applied 3 – 60 V external VCC source (or sink to ISO-GND). The 68DT1 can sense broken input connections and whether an input is shorted to +VCC or to ground. Additional features of the DT4 EF are listed below. The 68DT1 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for pull-up resistors or mechanical jumpers.
-
Unitech Scales And Measurements Pvt. Ltd
Current to Pressure Trainer. This setup comprises of a I to P converter fitted on a base. Two pressure gauges are fitted one at the input side and the other at the output of the I to P converter. A current source with digital display is provided to excite the I to P converter. A constant air supply should be provided to the system at 20 PsI Pressure from a standard compressor.
-
ZERA GmbH
We refer to test meters with an integrated source as test systems. Test systems are particularly useful when you need custom current and voltage values when testing meter installations, but only want to use a single device.
-
1260-120 -
Astronics Corporation
Each channel of the 1260-120 can switch up to 13A, 250VAC or 10A, 125VDC; its switching capability makes it the ideal solution for applications requiring high-current switching of AC power, DC power supplies, and AC or DC current sources.
-
TS41 -
Calmet Smart Calibration Devices
The Calmet TS41 test system consists of a three-phase reference meter of accuracy class 0.02% (or 0.04%) and an integrated three-phase current and voltage source up to 3x120A/600V. It makes possible automatic testing of electricity meters in meter test stations
-
MSXB 084 -
Microstar Laboratories, Inc.
The MSXB 084 Isolated Analog Input Expansion Board provides isolated analog inputs for DAP systems. Use these boards to eliminate ground currents – a potential source of noise in your measurement and control signals – and eliminate timing skew.
-
Hilkar
Nonlinear loads such as power electronics based equipment and electric furnaces are sources of harmonic currents leading to harmonic distortion, which is one of the most important parameters for defining the power quality. Most of the commercial loads such as personal computers, photocopy machines, power supplies, and compact fluorescent lamps; and industrial loads such as AC and DC motor drives inject harmonic currents into the network that they are connected to.